24.05.2020

Allen Bradley 525 Drive User Manual

65
Allen Bradley 525 Drive User Manual 4,7/5 9189 votes

PowerFlex® 4-Class HIM (DSI) Quick Reference

User Manual Powerflex 525.pdf - Free download Ebook, Handbook, Textbook, User Guide PDF files on the internet quickly and easily. Rockwell Automation 25B PowerFlex 520-Series Adjustable Frequency AC Drive User Manual User Manual. Powerflex 525 safe-torque-off operation. Rockwell Automation Equipment. The PowerFlex 525 Safe-Torque-Off function disables the drive’s output IGBT’s.

Human Interface Modules (HIM)

Display Descriptions

22-HIM-A3 — IP20 (NEMA Type 1) 22-HIM-C2S — IP66 (NEMA Type 4X/12)

Display

Status Line: Direction ” Operating Status ” Drive Status ” Auto/Manual Mode ” Parameters Locked/Unlocked

Process Display screen:

• Output Frequency

• User Display Line 1 (HIM Parameter 04)

• User Display Line 2 (HIM Parameter 05)

Programming screen

Menu Navigation Tabs

Large Format User Display screen:

SelEsc

Esc

7 8 9

4 5 6

1 2 3

. 0 +/-

Sel

Jog

Alt

Param #

View Lang Remove

DSI

Esc Sel

ALT

LANG

DISP

Jog

DSI

REMOVE

Esc Sel

ALT

LANG DISP

Jog

DSI

SELDIAG DSEL MEM

Changed Params

Linear List

Parameters

Groups

PARAM

Hz

A

V

F Stopped Auto

Hz

F At Reference Auto

Output Freq

NBA 2K16 PC Game has many modifications and additions from the last game. As it is a Basketball game and it is based on National Basketball Association. You can play this game as a real life team or the customized team made by yourself. You can compete with any team. There are many options provided for different aspects of the game. Nba 2k16 manual download. NBA 2K is back with the most true-to-life NBA experience to date with NBA 2K16. The NBA 2K16 Starter Pack Bundle includes NBA 2K16 and 75,000 VC. NBA 2K16’s in-game currency, VC, can be spent on your MyPLAYER, MyTEAM card packs, and more! Choose a Region and Platform: PS4™ U.S. Germany France Italy Spain Greece Australia Netherlands Korea. Choose a Region and Platform: Xbox 360® U.S. Germany France Italy Spain Greece Australia Netherlands.

Esc

7 8 9

4 5 6

1 2 3

. 0 +/-

Sel

Jog

Alt

Param #

View Lang Remove

DSI

Hz

A

V

F Stopped Auto

Key Descriptions

Menu Navigation Tabs

Keys Description

Exit a menu, cancel a change to a parameter value, or acknowledge a fault/alarm.

Select a digit, select a bit, or select a menu tab.

Scroll through options, increase a value, or toggle a bit.

Scroll through options, decrease a value, or toggle a bit.

Enter a menu, enter edit mode in a parameter screen, or save a change to a parameter

value.

plus…

Toggle between the Process Display and Large Format Display.

Select an available language for text displayed on HIM screens.

Allow the HIM to be disconnected without causing a fault condition.

Enable direct parameter number entry.

Start the drive.

Stop the drive or clear a fault.

Change direction.

Jog the drive.

Type parameter numbers and values.

Increase or decrease the speed Reference to the drive after these keys are enabled by

setting drive parameter P038 – [Speed Reference] as follows:

Allen bradley programming manual

• When the HIM is the DSI Master, set parameter P038 to “5” (Comm Port).

• When the HIM is the DSI Slave, set parameter P038 to “1” (Internal Freq).

To view the HIM’s active device type status (Master or Slave), see HIM Parameter 10 –

[M/S Status].

Tabs Description

DIAG The Diagnostics tab is used to display faults, the device (drive or peripheral) status, and device version.

PARAM The Parameters tab is used to edit parameters. Parameters can be displayed in groups, in a linear list,

or only those changed from their defaults.

DSEL The Device Select tab is used to select the device (drive or peripheral) that the HIM is to access.

MEM The Memory Storage tab is used for HIM CopyCat (uploading/downloading configurations to the HIM

EEPROM).

HIM The HIM Setup tab is used to access HIM parameters, view the HIM version, and to edit the Reference

text when a user-defined Reference is used.

Esc

Sel

Alt

Sel

View

Lang

Remove

+/-

Param #

Jog

…0 9

. +/-

Parameter List

Parameter

No. Name and Description Details

01 [Startup Display]

Selects the display screen shown when the HIM is powered up.

Default: 0 = Main Menu

Values 0 = Main Menu

1 = Process Disp

2 = Large Disp

3 = Startup Param

Type: Read/Write

02 [Startup Param]

Selects a desired drive parameter to be displayed if Parameter 01 –

[Startup Display] is set to “3” (Startup Param).

Default: 1

Minimum: 1

Maximum: 65535

Type: Read/Write

03 Reserved

04 [User Disp Line 1]

Selects a desired drive parameter to be displayed on User Display

Line 1 of the Process Display screen.

For example, setting to “3” selects PowerFlex 4-Class drive

Parameter 3 – [Output Current] to be displayed.

Default: 3

Minimum: 1

Maximum: 65535

Type: Read/Write

05 [User Disp Line 2]

Selects a desired drive parameter to be displayed on User Display

Line 2 of the Process Display screen.

For example, setting to “5” selects PowerFlex 4-Class drive

Parameter 5 – [DC Bus Voltage] to be displayed.

Default: 5

Minimum: 1

Maximum: 65535

Type: Read/Write

06 [Large Disp Param]

Selects a desired drive parameter to be displayed on the Large

Format User Display screen.

For example, setting to “1” selects PowerFlex 4-Class drive

Parameter 1 – [Output Freq] to be displayed. Setting to “0” enables

the Scaled Reference to be displayed.

Default: 1

Minimum: 0

Maximum: 65535

Type: Read/Write

07 [LCD Contrast]

Sets the HIM LCD contrast level.

Default: 50%

Minimum: 0%

Maximum: 100%

Type: Read/Write

08 [Reset HIM]

1 (Reset): Resets the HIM.

2 (Set Defaults): Resets HIM parameters to factory settings.

This parameter returns to a value of “0” (Ready) after the reset

function is complete.

Default: 0 = Ready

Values 0 = Ready

1 = Reset

2 = Set Defaults

Type: Read/Write

09 [Device Type]

Selects the HIM device type. When set to “0” (Auto), the HIM is

automatically configured as either a DSI Master or Slave depending

on the presence of other peripheral devices.

Default: 0 = Auto

Values 0 = Auto

1 = Slave

2 = Master

Type: Read/Write

10 [M/S Status]

Displays the HIM active device type.

Default: N/A

Values 1 = Slave

2 = Master

Type: Read Only

11 [HIM Ref Preset]

0 (Zero Start): HIM Reference is always “0.0” at power on.

1 (Host Output): HIM will assume the Host’s output feedback

(bumpless transfer) and preset its Reference when

the Reference is configured to be received on the

RS-485 port. This can be verified by viewing

Diagnostics/Device Status/Remote Freq Ref = 1.

2 (Last HIM Ref): HIM will store the HIM Reference in EEPROM each

time it is changed. HIM Reference is restored at

power on.

Default: 0 = Zero Start

Values 0 = Zero Start

1 = Host Output

2 = Last HIM Ref

Type: Read/Write

NOTE: New settings to HIM parameters are implemented immediately.

Resetting the HIM is not required for new values to take effect.

12 [Ref Scaling]

Allen Bradley 525 Vfd

Enables or disables scaling the Reference to a user-defined value.

When Parameter 12 – [Ref Scaling] is set to “1” (Enabled), use HIM

Parameters 13…22 to scale the Reference.

Default: 0 = Disabled

Values: 0 = Disabled

1 = Enabled

Type: Read/Write

13 [Ref Max Value]

Sets the user-defined value to be displayed when the drive is running

at 60 Hz.

Default: 600

Minimum: 100

Maximum: 65535

Type: Read/Write

14 [Ref Dec Position]

Sets the number of digits to be displayed to the right of the decimal

point for the Reference.

Default: 1

Minimum: 0

Maximum: 3

Type: Read/Write

15

16

17

18

19

20

21

22

[Ref Units Char 1]

[Ref Units Char 2]

[Ref Units Char 3]

[Ref Units Char 4]

[Ref Units Char 5]

[Ref Units Char 6]

[Ref Units Char 7]

[Ref Units Char 8]

Selects up to 8 characters (from the ISO 8859-1 character set) to use

for the Reference units on the Process Display.

Parameters 15…22 can also be configured using the “Edit Ref Text”

selection in the HIM Setup tab.

Default: 72 (“H”)

Default: 122 (“z”)

Default: 32 (blank – no character)

Default: 32 (blank – no character)

Default: 32 (blank – no character)

Default: 32 (blank – no character)

Default: 32 (blank – no character)

Default: 32 (blank – no character)

Minimum: 32

Maximum: 255

Type: Read/Write

Allen Bradley 525 Drive User Manual Free

23 [Fault Dspy Type]

Selects the type of display flash to be shown when a drive or

peripheral fault is detected.

Default: 0 = Flash Bklite

Values: 0 = Flash Bklite

1 = Flash None

Type: Read/Write

24 [Alarm Dspy Type]

Selects the type of display flash to be shown when a drive alarm is

detected.

Default: 1 = Flash None

Values: 0 = Flash Bklite

1 = Flash None

Type: Read/Write

Parameter

No. Name and Description Details

www.rockwellautomation.com

Americas: Rockwell Automation, 1201 South Second Street, Milwaukee, WI 53204-2496 USA, Tel: (1) 414.382.2000, Fax: (1) 414.382.4444

Europe/Middle East/Africa: Rockwell Automation, Vorstlaan/Boulevard du Souverain 36, 1170 Brussels, Belgium, Tel: (32) 2 663 0600, Fax: (32) 2 663 0640

Asia Pacific: Rockwell Automation, Level 14, Core F, Cyberport 3, 100 Cyberport Road, Hong Kong, Tel: (852) 2887 4788, Fax: (852) 2508 1846

Power, Control and Information Solutions Headquarters

Allen Bradley Programming Manual

U.S. Allen-Bradley Drives Technical Support

Tel: (1) 262.512.8176, Fax: (1) 262.512.2222, Email: support@drives.ra.rockwell.com, Online: www.ab.com/support/abdrives

Publication 22HIM-QR001F – September 2009

Supersedes 22HIM-QR001E-EN-P – April 2005 Copyright © 2009 Rockwell Automation, Inc. All rights reserved. Printed in USA.